841
you are viewing a single comment's thread
view the rest of the comments
view the rest of the comments
this post was submitted on 26 Aug 2023
841 points (94.0% liked)
Technology
59570 readers
3228 users here now
This is a most excellent place for technology news and articles.
Our Rules
- Follow the lemmy.world rules.
- Only tech related content.
- Be excellent to each another!
- Mod approved content bots can post up to 10 articles per day.
- Threads asking for personal tech support may be deleted.
- Politics threads may be removed.
- No memes allowed as posts, OK to post as comments.
- Only approved bots from the list below, to ask if your bot can be added please contact us.
- Check for duplicates before posting, duplicates may be removed
Approved Bots
founded 1 year ago
MODERATORS
We compensate for thermal expansion. The standard temperature things are measured at is 68F/20C. So if it's 72 degrees we'll compensate it back to 68 in software for the material we're measuring. We use scale bars of known length and similar material type to verify scale. (I run laser trackers and laser radars.)
For measurement equipment that's stationary, like CMMs, you just control the environment.