[–] Darkassassin07@lemmy.ca 1 points 2 days ago* (last edited 2 days ago)

CAFI breakers combine series and parallel arc fault detection (AFCI only detect parallel arcs). They DO NOT provide GFCI protection.

https://homeinspectioninsider.com/cafci/

Initially, AFCI devices were primarily required in bedrooms, as these areas were most prone to undetected arcing that could result in fires. However, as the need for increased protection became more evident, the requirement for AFCI or CAFCI devices expanded to all parts of your home.

The only exception is moisture-prone areas, such as bathrooms, kitchens, outdoor circuits, and laundry rooms. You might install a GFCI device instead of a CAFCI one in these areas. But as CAFCI technology advances, the goal is for them to replace GFCI devices eventually.

Ground Fault protection is still only required near water as far as I can find. Combination AFCI+GFCI breakers do exist, but they aren't actually required anywhere afaik. (and I've never seen one in person)

Got a reference handy?

Bored. For shits and giggles, I just tested one of the Combo AFCI breakers in my home. It does not trip when presented with a ground fault.