I don't know why this is such a hard combo to meet, but I can't seem to find anything that suits. I assume there's enterprise gear that would meet these points, but I'm not sure where to start.

POE is for running a half dozen POE cameras, 3x WIFI6 WAPs, Home Assistant Yellow. I could get away with running a separate POE switch if not for the WAPs (looking at the TP-Link AX11000's which are 10GbE). I could buy a UniFi XG 6 POE for just the WAPs and use another regular POE switch to give me enough ports, but that's just getting messy.

The ideal is to have a high density 10GbE managed switch that I can use for both my regular gear and POE gear (I have 20 ports to connect out to plus gear I might run in the rack). If the Unifi XG Enterprise had POE it would be perfect.

you are viewing a single comment's thread
view the rest of the comments
[-] 1Tekgnome@alien.top 1 points 11 months ago

Run "dm fan"

Here's mine

  • FRU 1 Fan 1 Speed at 5793 RPM.
  • FRU 1 Fan 2 Speed at 6553 RPM.
  • FRU 2 Fan 1 Speed at 5844 RPM.
  • FRU 2 Fan 2 Speed at 6192 RPM

As well as "show chassis"

Here's mine as well

  • The stack unit 1 chassis info:

  • Power supply 1 (AC - PoE) present, status ok

  • Model Number: 23-0000142-02

  • Serial Number: 9FK

  • Firmware Ver: A

  • Power supply 1 Fan Air Flow Direction: Front to Back

  • Power supply 2 (AC - PoE) present, status ok

  • Model Number: 23-0000142-02

  • Serial Number: 91G

  • Firmware Ver: A

  • Power supply 2 Fan Air Flow Direction: Front to Back

  • Fan 1 ok, speed (auto): [[1]]<->2

  • Fan 2 ok, speed (auto): [[1]]<->2

  • Fan controlled temperature: 61.5 deg-C

  • Fan speed switching temperature thresholds:

  • Speed 1: NM<----->76 deg-C

  • Speed 2: 71<-----> 80 deg-C (shutdown)

  • Fan 1 Air Flow Direction: Front to Back

  • Fan 2 Air Flow Direction: Front to Back

  • MAC 1 Temperature Readings:

  • Current temperature : 49.0 deg-C

  • MAC 2 Temperature Readings:

  • Current temperature : 56.5 deg-C

  • CPU Temperature Readings:

  • Current temperature : 61.5 deg-C

  • sensor A Temperature Readings:

  • Current temperature : 50.5 deg-C

  • sensor B Temperature Readings:

  • Current temperature : 53.5 deg-C

  • sensor C Temperature Readings:

  • Current temperature : 39.5 deg-C

  • stacking card Temperature Readings:

  • Current temperature : 53.5 deg-C

  • Warning level.......: 77.0 deg-C

  • Shutdown level......: 80.0 deg-C

[-] TorrentplsZOMG@alien.top 1 points 11 months ago

Amazing, thank you. But how do I set values for it?