[-] peregus@lemmy.world 7 points 2 weeks ago

Why not wasting 10 seconds to write something about the linked article?

[-] GreatAlbatross@feddit.uk 4 points 1 week ago* (last edited 1 week ago)

I'll write a quick gist for anyone coming along:

One gas boiler in the house, each room has a smart TRV.
PIR sensor to set room presence, each window has an opening mag sensor. HASS has a general presence sensor set.

Each room's temperature is targeted based on presence and window status:
For each room, if person is home at all, and has been in the room for 5 mins, and the window is closed, TRV to 19, boiler on if <19.
If the room presence is negative and the window is closed, drop TRV target to 16.
If the window is open, drop the TRV target to 7.

There is a little more detail that that in the article, but that's the basics.