If all you have is the serial number of the disk that is failing ... you'd better know what slot it's in before you go pulling disks for replacement.
The only thing I can think of is to put stickers.
Not in a position to try this right now, but if your server is a Dell and you have the (enterprise, possibly) iDRAC, I think you can make a light on the drive caddy blink so you can identify it.
i label my drives with the serial number. i can then easily remove the failed drive.
I tape a piece of paper with important info to the top of the server... Top outside, not the inside because I don't want it to block any airflow.
Paper is cheap and doesn't need batteries, and I don't need to look for the info when I need it.
If you use a generic case then you're going to have to gather the info outside.
Some suggestions:
Onenote or similar - use the rectangle tool to sketch up some rectangles of your drive bays and then type/write out the serial numbers and other info. I record manufacture date, when I installed it, where I bought it from, the part number, the serial number and sometimes a comment like "ironwolf pro orange logo sticker."
If you use a SAS HBA with breakout cables you may be able to identify them by port. Ie HP P822 tells you I:1:0 for internal port 1, breakout cable 0/1, E:2:1 for external port 2, breakout cable 2/1.
All my drives came with a sticker from WD with the serial number on the back of each drive. I am able to open my hot swap bays just enough to the number without disconnecting the drives.
Once my server was up and running I took a snapshot of all of the drives, shut off the server, and rearranged them from top to bottom following the order on the list. So disk 1 is in slot 1 and so on.
Last time I did this, i mapped out which plug corresponded to which device that linux saw then wrote a script that told me which hard drive was plugged into where and put it into a csv file.
This was for my disk testing tower, so when it told me "sdb" had finished badblocks, i would know which hdd sdb was.
Can you tell if the backplane supports SGPIO? If it and your RAID card do, and things are wired up correctly, you can tell your RAID card to Identify the drive and it'll blink the LEDs. I just configured a Supermicro chassis to do this with an Adaptec controller.
I add part of the serial number into the gpt label. Plus printed labels of that part of the serial on the drive bays.
I've started to utilize Netbox for all of that. Haven't gotten to the drives yet, but all my networking connections, power, IP's, etc. are documented in it.
Homelab
Rules
- Be Civil.
- Post about your homelab, discussion of your homelab, questions you may have, or general discussion about transition your skill from the homelab to the workplace.
- No memes or potato images.
- We love detailed homelab builds, especially network diagrams!
- Report any posts that you feel should be brought to our attention.
- Please no shitposting or blogspam.
- No Referral Linking.
- Keep piracy discussion off of this community